Measurement Tolerance Design for Operational Quality Control
Keywords:
operational control, measurement error, reliability, toleranceAbstract
The issues of measurement accuracy within operational control are considered. Analysis of the technical literature and standards show that there is a kind of "normative vacuum" concerning operational control. Implementing the methodology of final inspection to operational control is not correct because the objectives of final inspection and operational control do not match. Recommendations for standardization of measurement accuracy for a variety of problems solved within operational control are provided.References
Марков Н. Н., Кайнер Г. Б., Сацердотов П. А. Погрешность и выбор средств при линейных измерениях. - М. : Машиностроение, 1967. - 392 с.
Данилевич С. Б. Планирование выходного измерительного контроля качества продукции. - Новосибирск : Изд-во НГТУ, 2006. - 137 с.
Downloads
Published
15.06.2011
How to Cite
Solomakho Д. В., Tsitovich Б. В., & Sokolovsky С. С. (2011). Measurement Tolerance Design for Operational Quality Control. Vestnik IzhGTU Imeni M.T. Kalashnikova, (2), 51–54. Retrieved from https://izdat.istu.ru/index.php/vestnik/article/view/2250