Temperature Correction in the Relaxation Autogenerating Measuring Converter

Authors

  • E. D. Makshakov Sarapul Polytechnical Institute, Branch of Izhevsk State Technical University

Keywords:

equivalent RC two-terminal element, relaxation autogenerating converter, microcontroller, sensor of temperature, temperature correction

Abstract

A way to decrease a capacity measurement error, based on the temperature correction of the relaxation period of an autogenerating converter is offered. The study is directed to optimization of relaxation measuring converters for monitoring systems of RC-sensors. The developed scheme contains a microcontroller, temperature sensor and an equivalent RC two-terminal element.

Author Biography

E. D. Makshakov, Sarapul Polytechnical Institute, Branch of Izhevsk State Technical University

; Sarapul Polytechnical Institute, Branch of Izhevsk State Technical University

References

Макшаков Е. Д., Подкин Ю. Г. Измерение параметров диссипативных CG-двухполюсников // Информационное и техническое обеспечение информационных технологий : Материалы республиканской науч.-метод. очно-заочной конф. - Ч. 1. - Сарапул : Изд-во СПИ, 2010. - С. 61-70.

Подкин Ю. Г. Особенности проектирования модулей релаксационных преобразователей для систем контроля диэлектрических дисперсных материалов // Приборостроение и средства автоматизации. - 2004. ? № 1. ? С. 62?69.