Measurement of Force Parametersfor the Human Gait Study

Authors

  • T. S. Hussein Don State Technical University
  • A. I. Izyumov Don State Technical University

DOI:

https://doi.org/10.22213/2413-1172-2023-2-16-25

Keywords:

ground reaction forces GRF, pressure sensor, gait phases

Abstract

The study focuses on the fabrication of shoe sensors (MSS) that provides important information about the dynamic movement of the lower limbs. In this study the kinematic model of human lower limbs was analyzed to know and detect the changes during human gait phase, that occurs when walking, based on the GRF. The sensors number, sensor type and location of sensors was chosen to proceed on the MSS device. The algorithm was developed based on COP that is able to detect the gait phase by means of three sensors. The standard deviation and mean for COPy and vGRF values are expressed on the basis of walk of the five testees. It includes 4 gait phases: initial contact IC (1), mid-stance MS (2), terminal stance TS (3), and swing (4), the gait cycle detection is expressed as an average value. The experimental work is conducted to estimate the manufactured shoe sensor device and to detect the gait phase algorithm and compare it to an F-Socket sensor device (FSS). The results of the MSS device fabrication were (MS - mean value was 9.49 ± 2.76%, TS - mean value was 29.46 ± 4.95% and the swing mean value was 62.50 ± 1.60%) and the pressure result (255.629 KPа) while the result of the (FSS) device were (MS - mean value was 10.98 ± 1.74%, TS - mean value was 30.43 ± 2.32 %, and the swing mean value was 60.69 ± 1.74 %) and the pressure result (259.618 KPа) respectively, the test results showed that the results obtained from the (MSS) device are close to the readings obtained by using the (FSS) device, this shows the (MSS) device accuracy of this study despite the fact that it has simple design and inexpensive.

Author Biographies

T. S. Hussein, Don State Technical University

Postgraduate

A. I. Izyumov, Don State Technical University

PhD in Engineering, Associate Professor

References

Hertel J., Gay M.R., Denegar C.R. (2020) Differences in postural control during single-leg stance among healthy individuals with different foot types. Journal of athletic training, 2020, vol. 37, no. 2, 129 p.

Stefanou T., Chance G., Assaf T. (2018) Wearable tactile sensor brace for motion intent recognition in upper-limb rehabilitation. IEEE International Conference on Biomedical Robotics and Biomechatronics Biorob, 2018, pp. 148-155. DOI: 10.1109/BIOROB.2018.8487721

Li B., Xiang Q., Zhang X. (2020) The center of pressure progression characterizes the dynamic function of high-arched feet during walking. Journal of Leather Science and Engineering, 2020, vol. 2, pp. 1-10. DOI: 10.1186/s42825-019-0016-6

Perry J., Burnfield J. M. Gait Analysis: Normal and Pathological Function, SLACK Incorporated, 1992.

Hussein T.S., Izyumov A. (2022) A Unique Step towards Generation of Electricity by Amputees Persons.International Research Journal of Engineering and Technology, 2022, vol. 9, no. 5, pp. 694-700.

Thalman C.M., Hertzell T., Lee H. (2020) Toward a soft robotic ankle-foot orthosis (sr-afo) exosuit for human locomotion. IEEE International Conference on Soft Robotics, 2020, pp. 801-807. DOI: 10.1109/RoboSoft48309.2020.9116050

Хуссейн Т. С., Изюмов А. И. Измерение давления и анализ ортеза голеностопного сустава для человека с переломом лодыжки // Инженерный вестник Дона. 2022. № 4 (88). С. 590-601.

Renganathan G., Kurita Y., Ćuković S., Das S. (2022) Foot biomechanics with emphasis on the plantar pressure sensing. Advances in Product Design and Design Methods for Healthcare, 2022, pp. 115-141. DOI: 10.1007/978-981-16-9455-4_7

Хуссейн Т. С., Изюмов А. И. Микропроцессорная система измерения давления между ортезомистопой // Системы. Методы. Технологии. 2023. № 1 (57). С. 80-86. DOI: 10.18324/2077-5415-2023-1-80-86

Bergenthal M., Krafczyk N., Peleska J. (2022) An Open Source Library for FSM-Based Testing. Testing Software and Systems: International Conference, London, UK, Springer International Publishing, 2022. DOI: 10.1007/978-3-031-04673-51

Функциональная электростимуляция при восстановлении ходьбы после инсульта. Обзор научной литературы / Е. А. Гурьянова, В. В. Ковальчук, О. А. Тихоплав, Ф. Г. Литвак // Физическая и реабилитационная медицина. 2020. № 2 (3). С. 244-262.

Мухаммедова М. О. рекомендации по выбору типа обуви в зависимости от риска развития синдрома диабетической стопы // Вестник науки. 2022. № 4 (49). С. 122-129.

Дашевский И. Н., Никитин С. Е. Биомеханика разгрузки нижних конечностей при протезировании // Российский журнал биомеханики. 2016. № 20 (2). С. 134-149.

Смирнова Л. М., Юлдашев З. М. Измерительно-информационные системы для протезно-ортопедической отрасли // Биотехносфера. 2012. № 2 (20). С. 17-23.

Потенциальные преимущества и ограничения использования роботизированных экзоскелетов у пациентов, перенесших позвоночно-спинномозговую травму / Н. Н. Карякин, А. Н. Белова, В. О. Сушин, Г. Е. Шейко, Ю. А. Исраелян, Н. Ю. Литвинова // Вестник восстановительной медицины. 2020. № 2 (96). С. 68-78.

Ippisch R., Jelusic A., Bertram J. (2022) Mobile smartphone-based spatiotemporal gait analysis in healthy and ataxic gait disorders. Gait&Posture, 2022, vol. 97, pp. 80-85. DOI: 10.1016/j.gaitpost.2022.07.256

Ikuta Y., Nakasa T., Fujishita H. (2022) An association between excessive valgus hindfoot alignment and postural stability during single-leg standing in adolescent athletes. Sports Science, Medicine and Rehabilitation, 2022, vol. 14, no. 1. DOI: 10.1186/s13102-022-00457-7

López-López L., Navarro-Flores E., Losa-Iglesias (2022) Impact of chronic foot pain related quality of life: a retrospective case-control study. Pain Physician, 2022, vol. 26, no. 6, pp. E851-E856.

Fujiwara S., Sato S., Sugawara A. (2020) The coefficient of variation of step time can overestimate gait abnormality. Sensors, 2020, vol. 20, no. 3, p. 577. DOI: 10.3390/s20030577

Mazzetta I., Zampogna A., Suppa A. (2019) Wearable sensors system for an improved analysis of freezing of gait in Parkinson's disease using electromyography and inertial signals. Sensors, 2019, vol. 19, no. 4, 948 p. DOI: 10.3390/s19040948

Published

19.07.2023

How to Cite

Hussein Т. С., & Izyumov А. И. (2023). Measurement of Force Parametersfor the Human Gait Study. Vestnik IzhGTU Imeni M.T. Kalashnikova, 26(2), 16–25. https://doi.org/10.22213/2413-1172-2023-2-16-25

Issue

Section

Articles